I. Introduction
The Model ETP-WM and ETP-WM24 Wall Mount units are designed to house the Talk-A-Phone Blue Light and a
Talk-A-Phone 400-Series or 500-Series ADA compliant hands-free Emergency Phone.
II. Installation
To install the Wall Mount after site preparation (including telephone/data line and provision of power for the Blue
Light and faceplate light), follow these steps:
1. The Wall Mount is held to the wall with 4 #10 screws. Install two #10 screws in order to hold the top
section to the wall. Note that the screws should be located so that the Wall Mount will be at the
desired height and in the correct position to receive any conduit connections.
2. Electric power and the telephone/data line can be brought into the unit in one of two ways:
a. There are two large openings in the back of the unit to allow the unit to be mounted over a
standard flush-mounted electrical box and/or flush-mounted telephone connector box.
b. There are two conduit openings available on the bottom of the unit to feed the power and/or
telephone/data line inside the unit (Note: power and telephone/data lines cannot be ran in the
same conduit).
3. Remove the cap lid from the Wall Mount by removing the four #10 spanner security screws located
on the side of the unit. DO NOT remove the Lexan shield from the unit. Mount the unit on the wall
using the two keyholes on the top rear of the unit to the two screws mounted to the wall in step 1.
4. Install two additional #10 screws of the appropriate type in the holes in the lower rear of the unit.
Tighten all four screws.
5. Install conduit over the bottom hole(s) of the unit if method (b) is being used (see step 2) and bring
power line and/or telephone/data line inside the unit.
6. Wire incoming power to the faceplate light. The LED light board operates on 12V up to 120V AC/DC
and is non-polarity sensitive.
7. The 120VAC model ETP-EL (polycarbonate base) Blue Light can be connected to the 120VAC output
voltage of the power source. If using the ETP-EL12/24 (polycarbonate base) Blue Light, connect the
power cable to either the 12-24VDC or the 24VAC output voltage of the power source (shown in
Figure 1).
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE
APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE
CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS
INVOLVED
CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D’INSTALLATION
PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LES PRODUIT ET
SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS