I. Introduction
This PBX system is specially designed to accommodate Talk-A-Phone Emergency/Information Phones, both
analog and VoIP. Versatile and robust, these full-featured PBXs provide a complete head-end solution.
Each of these PBX systems ships preprogrammed from the factory per the requirements specified on the
submitted preference form.
Note:
Do NOT adjust any dipswitches or settings that are not outlined in the Installation Instructions. Talk-A-Phone
authorization is required for adjustment of such dipswitches and settings.
Iwatsu technical/installation documents may have been provided with this PBX Installation document. These Iwatsu
technical/installation documents are to be used only as a reference. Do NOT follow instructions on Iwatsu documents
unless instructed by a Talk-A-Phone technician.
II. Core
Components
Qty.
Iwatsu
Part No.
Description
1 IX-CME
Gateway
Controller
Cabinet
1 IX-PWSE
Main
Power
Supply
1
IX-408
8-Port
Digital
Station / 4-Port Trunk Card
1
IX-12KTD-3
Digital
Attendant
Phone
1 IX-CCU
Central
Control
Unit
Card
1
IX-CCSU
Central Control Sub Unit Card
III.
General Hardware Installation
To install the PBX-64 Phone System, after site preparation (including provision of power and CO / PSTN lines),
follow these steps:
1. Install the IX-PWSE Power Supply into the dedicated slot on the left side of the IX-CME by sliding it
between the left and right guide rails located on the lower shelf bracket. Make sure that the power
supply is inserted deep enough so that all of the connector pins make complete contact with those on
the backplane motherboard. Make sure the AC power cable attached to the IX-CME is pulled out to
the left and for easy access after power supply installation.
2. Secure the IX-PWSE to the upper and lower shelf brackets with two black zinc plated screws
provided with the IX-CME.
3. Ensure the green ground wires attached to the IX-PWSE are secure in place with the star washer
between the screw and the metal end of the green ground wire (Factory installed).
4. Mount the IX-CCSU daughterboard to the IX-CCU card by matching the CNCCSU1 to CNCCU1
connectors and CNCCSU2 to CNCCU2 connectors on the IX-CCU card and the IX-CCSU card
respectively.
5. Slide the IX-CCU/IX-CCSU cards into the slot marked CCU/CCSU at the bottom of the IX-CME
cabinet. Make sure that the card is inserted deep enough for all the connector pins to make complete
contact with those of the backplane motherboard. Secure the card stopper bracket (located next to
the left locking tab) with the screw provided.