I. Introduction
This manual is for a Power Charging System designed to provide power during the day to a Talk-A-Phone Co.
Emergency Phone System that receives power every night. At night, while the batteries are being charged, the
Power Charging System will continue to power the system.
The PCS-42-6 is specifically designed to provide power to a Talk-A-Phone tower enclosure (ETP-MT/R-PCS, ETP-
MT/R-PCS-WP, ETP-MTE-W, ETP-MTE-WP, WEBS-MT/R) or surface mount enclosure (ETP-SMW). The batteries
are sized to accommodate a cellular interface (ETP-CI) in a tower or surface mount, or a VoIP Phone (VOIP-500
Series) and wireless IP interface (VOIP-RF-FM-1100) in a surface mount enclosure only (no LED Blue Light).
II. Contents
Before beginning installation, make sure you have all the included components. Each PCS-42-6 package consists
of the following bill of materials as summarized below:
Qty.
Part Number
Description
1
86383
Battery Charger - 12VDC, 6A
1
68594
Battery - 42Ah
6
67524
Battery Terminal Connectors
– Ring, 1/4in, Crimp
4
4247
Screw - #8-32 x 0.5 L, Binder Head, Slotted
4
4248
Nut - #8-32, Hex, Machine
4
42767
Washer - External Tooth Lock Washer, # 10
III. Communication System Installation
All connections must meet National, Regional and Local Electrical Codes. Installation should only be performed by
qualified professional personnel. Step down transformer and DC-DC converters, if included, have connections for
multiple input and output voltages. Be sure to make your connections to the terminals labeled with the voltage that
you require. As a safety precaution, it is recommended that you make all connections while the 120VAC (or other
high-voltage) is turned off. The battery may need one charge cycle before the system will function completely. It
may be convenient to charge the battery in advance.
Make all electrical connections according to the wiring schematic in Figure1 as well as any instructions included
with the individual electrical components:
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE
APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE
CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS
INVOLVED
CE
PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D’INSTALLATION
PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LES PRODUIT ET
SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS