Software Programming
Page 6 of 16
Talk-A-Phone Co.
Remote Mode
In Remote Mode, if you have plugged a standard telephone company phone
line into the TELCO IN port, you do not need to program the EC-8. Move on to
Programming your Emergency/Information Phones.
If you are using a PBX line in the TELCO IN port: you must program the EC-8
for PBX mode :
1. Call your EC-8 (listen for 3 beeps)
2. Enter Guard Access Code: *31**
3. Program the Consolidator for a PBX line: *39*2*
4. Move on to Programming your Emergency/Information Phones
Local Mode
1. Pick up the LOCAL PHONE (listen for 3 beeps)
2. Enter Guard Access Code: *31**
3. Program the Consolidator for Local Mode: *37*
4. Move on to Programming your Emergency/Information Phones
Day/Night Mode
1. Call your EC-8 or pick up the handset connected to the LOCAL PHONE port
(listen for 3 beeps)
2. Enter Guard Access Code: *31**
3. Program the Consolidator for Day/Night Mode: *63*
4. Program the Consolidator to call either:
Local first, then Remote: *35*
Remote first, then local: *36*
5. If you are using a PBX line in the TELCO IN port enter the PBX code: *39*2*
6. Move on to Programming your Emergency/Information Phones
C. Programming the Emergency/Information Phones
Once the Consolidator has been programmed, each Emergency/Information
phone must be programmed individually. You can route your call to the
desired phone port by entering the following code:
*4X* Routes to Emergency/Information phone in port jack number X (X=1-8)
For details on programming the Emergency/Information phones, refer to the
Installation & Operation Manual for Emergency/Information phones. (Note: if
your Consolidator is in Remote Mode or Day/Night Mode and your remote
phone line is a PBX extension, be sure to program your phones for Mode 2. See
Emergency Phone Manual, pages 11 and 15 for more information on Modes).