Manual-27 – Rane SR 4 User Manual
Page 27
Manual-27
Stored Parameter List (SPL)
Below is a table of stored parameters followed by descriptions of each parameter.
Index Description
Range of Values
Factory Setting Meaning
1
Auto Level
0 – 1
1
disabled - enabled
2
Auto Selection - Knob Push & Turn
0 – 1
1
disabled - enabled
3
Auto Lock
0 – 1
1
disabled - enabled
4
Baud Rate
0 – 4
2
0 = 9600, 1 = 19200, 2 = 38400, 3 = 57600, 4 = 115200
5
RW 485 Transmit Delay
2 – 200
10
2 - 200 ms
6
Maximum Number of Selections
1 – 8
8
1 – 8 Selections, ignored if SPL 2 & 9 disabled.
7
Knob Push & Turn Selection Roll
0 – 1
0
disabled - enabled
8
Knob Push & Turn Update on Release
0 – 1
1
disabled - enabled
9
Auto Selection - Knob Bump
0 – 1
0
disabled - enabled
10
Knob Bump Update Timer
0 – 5
3
0 - 5 seconds, ignored if SPL 9 disabled.
5. This parameter sets the minimum time in milliseconds the remote waits after
receiving a RW 485 message before it transmits a response. It is recommended
that this value not be changed. The default setting can be restored by holding the
encoder in during power-up for several seconds until the encoder LED turns on.
6. Maximum Number of Selections configures the number of selections that can be
accessed by the encoder (Knob Push & Turn and/or Knob Bump). This parameter
is ignored if both parameters 2 and 9 are disabled.
7. Knob Push & Turn Selection Roll configures the action taken when the last (bot-
tom) selection is reached and the encoder is pushed an turned. When enabled,
the selection wraps around from last to first (or first to last, depending on encoder
direction. This parameter is ignored if parameter 2 is disabled.
8. Knob Push & Turn Update on Release configures when the selection index is
updated after the encoder is pushed in and turned. When enabled, the SR updates
its selection index when the encoder is released, rather than updating each time the
encoder is turned. This parameter is ignored if parameter 2 is disabled.
9. Auto Selection - Knob Bump configuration affects the result of bumping the
encoder (pushing and releasing the encoder without turning). When enabled,
the next selection is automatically chosen; the selection index is updated after the
update timer expires. Selections automatically roll from last to first. Configuration
of this parameter affects the commands IS and ISR. See Encoder Input Commands
section for details.
10. Knob Bump Update Timer determines how long the remote waits before updating
its selection index once the encoder is released. Setting this value to 0 updates the
index instantly, with every press/release combination of the encoder. Increasing this
value allows users to scroll through and preview selections without updating the
index on every press. This parameter is ignored if parameter 9 is disabled.