Stored Parameter List (SPL)

Below is a table of stored parameters followed by descriptions of each parameter.

Index Description

Range of Values

Factory Setting Meaning

1

Auto Level

0 – 1

1

disabled - enabled

2

Auto Selection - Knob Push & Turn

0 – 1

1

disabled - enabled

3

Auto Lock

0 – 1

1

disabled - enabled

4

Baud Rate

0 – 4

2

0 = 9600, 1 = 19200, 2 = 38400, 3 = 57600, 4 = 115200

5

RW 485 Transmit Delay

2 – 200

10

2 - 200 ms

6

Maximum Number of Selections

1 – 8

8

1 – 8 Selections, ignored if SPL 2 & 9 disabled.

7

Knob Push & Turn Selection Roll

0 – 1

0

disabled - enabled

8

Knob Push & Turn Update on Release

0 – 1

1

disabled - enabled

9

Auto Selection - Knob Bump

0 – 1

0

disabled - enabled

10

Knob Bump Update Timer

0 – 5

3

0 - 5 seconds, ignored if SPL 9 disabled.

5. This parameter sets the minimum time in milliseconds the remote waits after

receiving a RW 485 message before it transmits a response. It is recommended

that this value not be changed. The default setting can be restored by holding the

encoder in during power-up for several seconds until the encoder LED turns on.

6. Maximum Number of Selections configures the number of selections that can be

accessed by the encoder (Knob Push & Turn and/or Knob Bump). This parameter

is ignored if both parameters 2 and 9 are disabled.

7. Knob Push & Turn Selection Roll configures the action taken when the last (bot-

tom) selection is reached and the encoder is pushed an turned. When enabled,

the selection wraps around from last to first (or first to last, depending on encoder

direction. This parameter is ignored if parameter 2 is disabled.

8. Knob Push & Turn Update on Release configures when the selection index is

updated after the encoder is pushed in and turned. When enabled, the SR updates

its selection index when the encoder is released, rather than updating each time the

encoder is turned. This parameter is ignored if parameter 2 is disabled.

9. Auto Selection - Knob Bump configuration affects the result of bumping the

encoder (pushing and releasing the encoder without turning). When enabled,

the next selection is automatically chosen; the selection index is updated after the

update timer expires. Selections automatically roll from last to first. Configuration

of this parameter affects the commands IS and ISR. See Encoder Input Commands

section for details.

10. Knob Bump Update Timer determines how long the remote waits before updating

its selection index once the encoder is released. Setting this value to 0 updates the

index instantly, with every press/release combination of the encoder. Increasing this

value allows users to scroll through and preview selections without updating the

index on every press. This parameter is ignored if parameter 9 is disabled.