WARNING

High voltage exposure. Use caution to avoid

personal injury during this procedure.

Double Element, Simultaneous, Single Phase

Operation.

Water In Tank Is Cold Or Not Enough Hot

Water With Power ON.
1. This procedure assumes line voltage,

ECO and elements are in working order.

2. Adjust temperature setting for both

thermostats to the highest setting.

3. Turn power “ON” to water heater.
4. Set multi-meter to “Volts AC”
5. Check across terminals L4 and T2 of

upper thermostat (see illustration 35).

A) Rated voltage NOT present,

Recheck upper ECO

(see page 14). If ECO

is okay, replace upper thermostat.

B) Rated voltage IS present,

proceed to next step.

6. Check across upper element terminals

(see illustration 36).

A) Rated voltage NOT present,

check wire connections from

thermostat to upper element.

B) Rated voltage IS present,

Repeat element testing

see page 15.

7. Check across terminal L3 of upper thermostat

and T2 of lower thermostat (see illustration 37).

A) Rated voltage NOT present,

Check ECO (see page 14) & wire

connections at upper & lower

thermostats. If okay,

replace lower thermostat.

B) Rated voltage IS present,

proceed to next step.

8. Check across lower element terminals

(see illustration 38).

A) Rated voltage NOT present,

check lower element wire

connections to the thermostats.

B) Rated voltage IS present,

Repeat lower element testing

see page 15

Illustration 35

Illustration 36

Illustration 37

Illustration 38

WARNING

Be sure thermostats are reset to

their original temperature settings

as found prior to thermostat

testing

Page 27

SERVICE PROCEDURE RE-IV

Light Duty Commercial

Thermostat Testing