Bradford White DB-80R3DS User Manual

Page 17

background image

WARNING

High voltage exposure. Use caution to avoid

personal injury during this procedure.

Double Element, Non-Simultaneous, Single Phase

Operation.

Water In Tank Is Cold With Power ON.
1. This procedure assumes line voltage, ECO and

elements are in working order.

2. Turn power “ON” to water heater.

3. Set multi-meter to “Volts AC”.

4. Check across terminals L4 and T2 of

upper thermostat (see illustration 8).

A) Rated voltage NOT present,

Recheck ECO. If ECO is okay,

replace thermostat.

B) Rated voltage IS present,

proceed to next step.

5. Check across element terminals

(see illustration 9).

A) Rated voltage NOT present,

check wire connections from

thermostat to element.

B) Rated voltage IS present,

Repeat element testing

see page 15.

Illustration 8

Tank Does Not Deliver Enough Hot Water.
1. This procedure assumes line voltage, ECO and

elements are in working order.

2. Turn power “ON” to water heater and set multi-meter to “Volts AC”.
3. Adjust temperature setting of upper thermostat to the highest setting.

Water temperature in tank must be below thermostat setting for this test.

4. See illustration 8 above, check voltage across terminals L4 and T2 of upper

thermostat.

A) Rated voltage IS present, okay, upper thermostat is

calling for heat. Go to step 5 below.

B) Rated voltage NOT present, replace upper thermostat.

5. Adjust temperature setting of upper thermostat to the minimum setting.

Water temperature in tank must be above thermostat setting for this test.

6. Check voltage across terminals L4 and T4 of upper thermostat

(see illustration 10).

A) Rated voltage NOT present, replace upper thermostat.
B) Rated voltage IS present, thermostat is okay. Go to step 7 on next page.

Illustration 9

Illustration 10

Page 17

SERVICE PROCEDURE RE-III

Residential Thermostat Testing

17