Double Element, Non-Simultaneous, Single Phase,

Off Peak Operation.

Water In Tank Is Cold With Power ON.
1. This procedure assumes line voltage,

ECO and elements are in working order.

2. Turn power “ON” to water heater.
3. Set multi-meter to “Volts AC”.
4. Check across terminals L4 and T2 of

upper thermostat (see illustration 24).

A) Rated voltage NOT present,

Recheck ECO (see page 14).

If ECO is okay, replace thermostat.

B) Rated voltage IS present,

proceed to next step.

5. Check across element terminals

(see illustration 25).

A) Rated voltage NOT present,

check wire connections from

thermostat to element.

B) Rated voltage IS present,

Repeat element testing

see page 15.

Illustration 24

Illustration 25

Tank Does Not Deliver Enough Hot Water.
1. This procedure assumes line voltage, ECO and elements are in

working order. Be sure OFF PEAK meter has not interrupted

line voltage.

2. Turn power “ON” to water heater and set multi-meter to “Volts AC”.
3. Adjust temperature setting of upper & lower thermostat to the

Highest setting. Water temperature in tank must be below thermostat

setting for this test.

4. See illustration 24 above. Check voltage across terminals L4 & T2 of

upper thermostat.

A) Rated voltage IS present, okay, upper thermostat is calling

for heat. Go to step 5 below.

B) Rated voltage NOT present, replace upper thermostat.

5. Adjust temperature setting of upper thermostat to the minimum

setting. Water temperature in tank must be above thermostat setting

for this test.

6. Check voltage across terminals T4 of upper thermostat & L1 of lower

thermostat (see illustration 26).

A) Rated voltage NOT present, replace upper thermostat.
B) Rated voltage IS present, upper thermostat is okay. Go to

step 7 on next page.

Illustration 26

WARNING

High voltage exposure. Use caution to avoid

personal injury during this procedure.

Page 23

SERVICE PROCEDURE RE-III

Residential Thermostat Testing

23