beautypg.com

Bradford White DB-80R3DS User Manual

Page 25

background image

SERVICE PROCEDURE RE-IV

Light Duty Commercial

Thermostat Testing

WARNING

High voltage exposure. Use caution to avoid

personal injury during this procedure.

Double Element, Non-Simultaneous, Single Phase

Operation.

Water In Tank Is Cold With Power ON.
1. This procedure assumes line voltage, ECO and

elements are in working order.

2. Turn power “ON” to water heater.
3. Set multi-meter to “Volts AC”.
4. Check across terminals L4 and T2 of

upper thermostat (see illustration 29).

A) Rated voltage NOT present,

Recheck ECO (see page 14). If

ECO is okay, replace thermostat.

B) Rated voltage IS present,

proceed to next step.

5. Check across element terminals

(see illustration 30).

A) Rated voltage NOT present,

check wire connections from

thermostat to element.

B) Rated voltage IS present,

Repeat element testing

see page 15.

Illustration 29

Illustration 30

Tank Does Not Deliver Enough Hot Water.
1. This procedure assumes line voltage, ECO and elements are in

working order.

2. Turn power “ON” to water heater and set multi-meter to “Volts AC”
3. Adjust temperature setting of upper & lower thermostat to the

Highest setting. Water temperature in tank must be below thermostat

setting for this test.

4. See illustration 29 above. Check voltage across terminals L4 & T2 of

upper thermostat.

A) Rated voltage IS present, okay, upper thermostat is calling

for heat. Go to step 5 below.

B) Rated voltage NOT present, replace upper thermostat.

5. Adjust temperature setting of upper thermostat to the minimum

setting. Water temperature in tank must be above thermostat setting

for this test.

6. Check voltage across terminals L3 & T4 of upper

thermostat (see illustration 31).

A) Rated voltage NOT present, replace upper thermostat.
B) Rated voltage IS present, upper thermostat is okay. Go to

step 7 on next page.

Illustration 31

Page 25

25