Bradford White DB-80R3DS User Manual

Page 22

background image

Double Element, Simultaneous, Three Phase

Operation (continued).

Water Temperature In Tank Is Above Thermostat

Setting.
1. This procedure assumes Line voltage, ECO and

elements are in working order.

2. Adjust upper and lower thermostat to the lowest setting.

3. Turn power “ON” to water heater.

4. Set multi-meter to “Volts AC”.

5. Check across terminals L4 and T2 of

upper thermostat (see illustration 22).

A) Rated voltage IS present,

replace upper thermostat.

B) Rated voltage NOT present,

upper thermostat is okay. Go to step 6 below.

C) Lower than rated voltage IS present,

recheck for grounded upper element

(see page 15).

6. Check across terminals L4 and T2 of

lower thermostat (see illustration 23).

A) Rated voltage IS present,

replace lower thermostat.

B) Rated voltage NOT present,

lower thermostat is okay.

C) Lower than rated voltage IS present,

recheck for grounded lower element

(see page 15).

Illustration 22

WARNING

High voltage exposure. Use caution to avoid

personal injury during this procedure.

Illustration 23

Page 22

SERVICE PROCEDURE RE-III

Residential Thermostat Testing

22