Specifications, Vent tables – Bradford White U-TW4-75S-76R-3N User Manual
Page 9
Page 9
Vent Tables
Venting Specifications for:
40 Gallon
50 Gallon
60 Gallon
2” Diameter (5.1 cm) PVC Vent Connector Lengths
Terminating #
of Elbows
Maximum Straight
Length ft (m)
Minimum Straight
Length ft (m)
Through the Wall
1
45 (13.7)
2 (0.6)
Through the Wall
2
40 (12.2)
2 (0.6)
Through the Wall
3
35 (10.7)
2 (0.6)
Through the Wall
4
30 (9.2)
2 (0.6)
Through the Roof 0
50 (15.2) 7
(2.1)
Through the Roof
1
45 (13.7) 7
(2.1)
Through the Roof
2
40 (12.2) 7
(2.1)
Through the Roof
3
35 (10.7) 7
(2.1)
Through the Roof
4
30 (9.2) 7
(2.1)
3” Diameter (7.6 cm) PVC Vent Connector Lengths
Terminating #
of Elbows
Maximum Straight
Length ft (m)
Minimum Straight
Length ft (m)
Through the Wall
1
115 (35.0)
10 (3.1)
Through the Wall
2
110 (33.5)
10 (3.1)
Through the Wall
3
105 (32.0)
10 (3.1)
Through the Wall
4
100 (30.5)
10 (3.1)
Through the Wall
5
95 (29.0)
10 (3.1)
Through the Roof 0
120 (36.6)
15 (4.6)
Through the Roof
1
115 (35.0)
15 (4.6)
Through the Roof
2
110 (33.5)
15 (4.6)
Through the Roof
3
105 (32.0)
15 (4.6)
Through the Roof
4
100 (30.5)
15 (4.6)
Specifications