beautypg.com

Pilot maintenance – Bradford White U-TW4-75S-76R-3N User Manual

Page 22

background image

Page 22

Burner Cleaning Procedure (cont’d)

Step

11. Thoroughly inspect burner screen and

burner venturi and remove any loose debris accumu-
lation. Inspect burner screen for any openings larger
than the normal screen openings.

Step 12.

Use compressed air and/or a vacuum to

remove any scale or other debris accumulation from
the burner screen and venturi.

Step 13.

Disconnect (unscrew) manifold mount from

feed line. Use a stiff brush, compressed air and/or vac-
uum to remove any debris build up from the manifold
mount.

Step 14.

Remove main burner orifice from feed line

(3/8” wrench). Inspect and clean if necessary.

Step 15.

Reassemble the burner assembly and reinstall into the water

heater. Restore gas supply and check for gas leaks.

Step 16.

To resume operation, follow the instructions located on the wa-

ter heater lighting instruction label. Or, use the lighting instructions located
in the water heater installation and operating manual.

Pilot Inspection, Testing and Replacement

Step

1.

Move the gas control

power switch to the “OFF” position

Pilot Maintenance

Gas control power

switch

Burner screen

Burner venturi

Manifold mount

Feedline

Main burner orifice

22