Step 5.

Disconnect yellow wires from the pres-

sure switch.

Step 6.

Reconnect wires from step 5 to new pressure switch.

Step 7.

Reconnect tubing to new pressure switch.

Step 8.

Carefully position pressure switch into blower housing.

Step 9.

Position gas control power switch to the “ON” postion and verify

proper heater operation.

Step 10.

Replace control access cover form step 2.

Blower Testing

Step 1.

Move the gas control power switch to the

“ON” position and adjust control to call for heat.

Step

2.

Remove the three screws (Phillips screw

driver) from the control access cover on the blower as-
sembly and remove cover.