Page 8

Power Supply

Dedicated 115VAC, 60 Hz, 15A.

Gas Supply Pipe

Minimum 1/2” NPT (schedule 40 black iron pipe recommended).

Approved Gas Type

Natural Gas.

Gas Pressure

6.0” W.C. minimum, 11.0” W.C. maximum.

Venting System

Power vent through the wall or vertical through the roof.

Approved Vent Materials PVC, CPVC or ABS.

Minimum clearance for
Servicing

18” from top, 24” from front, 4” sides and rear.

Water Supply Pressure

150 PSI maximum allowable working pressure. Check local codes for
supply pressure.

TCO Limit

Residential 188

o

F (87

o

C), Commercial 199

o

F (93

o

C).

Residential Temperature
Set Point Range

60

o

F (16

o

C) to 160

o

F (71

o

C) (approximate temperatures).

Commercial Tempera-
ture Set Point Range

80

o

F (27

o

C) to 180

o

F (82

o

C) (approximate temperatures).

Blower Temperature
Switch

Normally closed, opens @ 165

o

F (74

o

C), auto reset @130

o

F (54

o

C)

Pressure Switch

UTW1 Models:

Normally open, closes on vacuum increase @ -0.68, opens on vacuum
decrease @ -0.65

U4TW Models:

Normally open, closes on vacuum increase @ -0.83, opens on vacuum
decrease @ -0.80

U2TW & UTW4 Models:

Normally open, closes on vacuum increase @ -1.28, opens on vacuum
decrease @-1.25

Blower

U1TW & U4TW Models:

115VAC, 60Hz, 3.1 amps, 3000 RPM, 42 CFM @ 1.5” W.C.

U2TW & UTW4 Models:

115VAC, 60Hz, 3.1 amps, 3000 RPM, 68 CFM @ 0.4” W.C.

Specifications