Blower Removal

Step 1.

Move the gas control power switch to the

“OFF” position.

Step 2.

Unplug the water heater from the wall out-

let.

Step 3.

Disconnect vent system

from exhaust adapter on top of blower.

Step 4.

Remove exhaust adapter

from blower (blade screw driver) and retain for
use on new blower.

Step 5.

Remove dilution air clip from air in-

take boot and retain for use on new blower.

Step 6.

Unplug cord sets from blower.

Step

7.

Remove the three blower

mounting screws (1/4” nut driver).

Step 8. Remove blower with gasket from water heater.

Blower Installation

Step 9.

Clean any debris from jacket head of

water heater

Step 10. Set new blower with gasket
in place using locating pins on blower flange to line
up with location holes in jacket head. Be sure not to
damage gasket.

Gas control power

switch

TTW (water heater)

power cord

Blower cord

sets

Blower mount-

ing screws

Remove exhaust

adapter and retain

for use on new

blower

Remove dilution air

clip and retain for

use on new blower

Locating pins on

blower flange

Pin location holes

in jacket head

Blower Replacement

30