Blower Installation (cont’d)

Step 11.

Secure blower in place using mounting screws from step 7.

Step 12.

Reinstall exhaust adapter from step 4.

Step 13.

Reinstall dilution air clip from step 5.

Step 14.

Reconnect vent system to exhaust adapter.

Step 15.

Reconnect cords from step 6.

Step 16.

Position gas control power switch to the “ON” position.

Step 17.

Verify proper blower operation.

Blower Temperature Switch Testing

Step 1.

Move the gas control power switch to the

“OFF” position.

Step 2.

Remove the three screws (Phillips screw

driver) from control access cover on blower and remove
cover.

Step 3.

Locate the blower temperature switch.

Gas control power

switch

Control access

cover

Blower temperature

switch location

Air mixing

inlet

WARNING

115 volt potential exposure. Use caution making voltage checks to avoid

personal injury.

Blower Temperature Switch Testing

31