Specifications
Wiring Diagram
Control Timings
Ignition State
Timing
Pre-purge
15 seconds
Trial for Ignition
90 seconds
Flame Stabilization Period
3 seconds
Inter-purge
15 seconds
Flame Failure Response Time
1.5 seconds (2 second maximum, 1 second minimum)
Post-purge
15 seconds
PS Fault Delay (failed open/close)
Retry after 2 minutes
Soft Lockout
Retry after 5 minutes
TCO Limit Lockout
Indefinite (see page 34 to reset)
Verify Resistive Delay
Retry after 2 minutes (repeats 5 times)
Simulated Resistive Load Lockout
Indefinite (cycle power to reset)
Hardware Error Lockout
Indefinite (self clears if fault clears for at least 15 seconds)