LED Status

Control Status

Probable Cause

Service Procedure

Six flashes,

one flash,

three second

pause (Soft

Lockout)

Failed to light pilot,

system resets after

(5) minutes

1. Unstable pilot

2. Pilot tube block or restricted

3. Oxidation build-up on pilot

electrode

4. Wire damage to pilot

assembly or bad connection at

gas valve

1. See Burner Inspection
on page 20
2-4. See Pilot Inspection,
Testing and Replacement
on page 22

Six flashes,

tw o flashes,

three second

pause (Soft

Lockout)

Pressure sw itch or

blow er temperature

sw itch opened

during burner

operation. System

resets after (5)

minutes

1. Vent blockage or improper
vent configuration
2. Pressure sw itch tubing kinked
or blocked
3. Faulty pressure sw itch
4. Vent termination being
affected by w ind
5. Blow er not spinning up to
speed
6. Blow er temperature or
exhaust temperature too high
7. Faulty blow er temperature
sw itch

1. Check vent or vent
tables
2-3. See Pressure Sw itch
Testing on page 25
4. Refer to venting section
of installation manual
5. See Blow er Testing on
page 28
6-7. See Blow er
Temperature Sw itch
Testing on page 31

Six flashes,

three

flashes,

three second

pause (Soft

Lockout)

Pilot flame

extinguished,

system auto resets

after (5) minutes

1. Unstable pilot
2. Pilot tube block or restricted
3. Oxidation build-up on pilot
electrode
4. Wire damage to pilot
assembly or bad connection at
gas control
5. Insufficient combustion air
6. Insufficient gas pressure

1. See Burner Inspection
on page 20
2-4. See Pilot Inspection,
Testing and Replacement
on page 22
5. Refer to Installation &
Operation Manual

Six flashes,

four flashes,

three second

pause

Undesired false

pilot flame sensed,

system auto resets

Pilot valve stuck in open position Replace gas control

Seven

flashes,

three second

pause

Flammable vapor

sensor or

resettable thermal

sw itch fault

detected, see

w arning label

1. Flammable vapor present
2. Flammable vapor sensor
exposed to excessive moisture
3. Flammable vapor sensor
exposed to extreme ambient
temperature
4. Resettable thermal sw itch
open

See Flammable Vapor
Sensor Testing on page 40

Eight

flashes, one

flash, three

second

pause

Flammable vapor

sensor out of

specification,

possible short

1. Flammable vapor sensor out
of specification; verify Flammable
Vapor Sensor (FVS) resistance is
not below 25 kŸ.
2. Possible short in flammable
vapor sensor or resettable
thermal sw itch w iring

See Flammable Vapor
Sensor Testing on page 40

Troubleshooting