Page 39

Gas Control Assembly to the Thermal Well (cont’d)

Step 2.

Route the wire leads back into relief opening.

Step 3.

Align the slots located on the thermal well flange

with the tabs located on the back of the gas control.

Step 4.

Carefully push the gas control back onto the thermal well flange as far as

possible towards the water heater. Then, slide the gas control down to lock into posi-
tion.

Step 5. Install the burner assembly
and connect the pilot and main feedlines
to the gas control using a 7/16” and 3/4”
wrench, respectively.

Step 6.

Reconnect the wire harnesses to the gas control.

Step 7.

Reconnect the gas piping to the gas control. Re-

store the gas supply and check for gas leaks.

Gas Control Assembly

Wire leads on

thermal well

Relief opening

Slots in thermal well

Tabs on back of gas

control

Pilot and main

feedlines

Wire harnesses