7-5

Appendix

Specifications

+3.3V

0.1

µF

10k

10k

10k

Internal contr

o

ller

Input terminals

IN

+

, IN

Output terminals

OUT A, OUT B

+

External Device I/O Terminals

You can use Input/Output external devices together with the Multi-Terminal Module (VB-EX50).

External Device Input Terminals (IN

+

, IN

)

The external device input terminals consist of 2 terminals (IN

+

, IN

-

). The ‘–’ terminal is grounded

on the inside of the main unit. By connecting 2 cables to the + and ‘–’ terminals and then electrically

short-circuiting across the terminals (ON) or separating the connection (OFF), an interrupt can be

generated for the internal controller. See “Schedule Setting Tool” in Chapter 4 “VB Administration

Tools” (

→ P.4-27) for information on the settings.

Connect any sensors and switches to terminals with electrically separate GND terminals and

power supplies.

External Device Output Terminals (OUT A, OUT B, OUT C)

The external device output terminals consist of 3 terminals (OUT A, OUT B, OUT C). There is no

distinction between “+” and “–” with OUT A, OUT B and OUT C. The Internal controller switches

the 2 output terminals to disconnected or connected condition. The output terminals use photo

couplers and are separate from the internal circuit in the VB-C50Fi.

* External input status can be checked and external output status can be controlled using Admin Viewer

(

→ P.4-65).

Loads connected to the output terminals should be within the following ratings:

Rating across the output terminals: Up to 50 V DC

Continuous load current: 100 mA

Internal Connection Chart

Tip

You need the Multi-Terminal Module (VB-EX50) (

→ P.1-10) to set input/output external

device.