Alarm Codes

High temperature
alarm

Press the “Up” or “Down” arrow once to change
screen from alarm to normal Temperature and
Humidity indication. “Hi Temp” will remain on
screen until temperature falls below the high
temperature alarm setpoint (Setting 3).





Low temperature
alarm

Press the “Up” or “Down” arrow once to change
screen from alarm to normal Temperature and
Humidity indication. “Lo Temp” will remain on
screen until temperature rises above the low
temperature alarm set point (Setting 2).





High humidity alarm



Press the “Up” or “Down” arrow once to change
screen from alarm to normal Temperature and
Humidity indication. “Hi Hum” will remain on
screen until humidity falls below the high
humidity alarm setpoint (Setting 5).




Low humidity alarm

Press the “Up” or “Down” arrow once to change
screen from alarm to normal Temperature and
Humidity indication. “Lo Hum” will remain on
screen until humidity rises above the low
humidity alarm setpoint (Setting 4).




Open Fault

Press the “Up” or “Down” arrow once to change
screen from alarm to normal temperature and
humidity indication.

THIS ALARM FORCES THE SYSTEM TO
SHUT DOWN.

“Alarm” will remain on screen until the High
Pressure reset switch has been reset. See the
trouble shooting guide page 55 for “Instructions
to Reset High Pressure Switch.”