beautypg.com

Joining communication cable, Changing jumper positions – Vintage Cellars Wine Guardian Ducted System Manual User Manual

Page 35

background image

35

Joining Communication Cable





Changing Jumper Positions

(Averaging readings from remote sensor)






























If using multiple remote temperature/humidity
sensors in your application, refer to the photos
showing the need to change the jumper locations
internal to the control board on each remote sensor
(up to three maximum).

For the control to average all of the sensors utilized
(if more than one), the jumper must be in different
positions on the pins.

As you can see, there are three pin settings. To access
the jumper:

1. Remove the two-set screws holding on the
plastic cover. This procedure allows the control
to go to each remote sensor in sequence to
average. Failure to perform this procedure will
result in the system reading only one sensor
and not the average of multiple sensors.

NOTE: If multiple sensors control the Wine
Guardian unit, change factory default in
configuration setting 10 to “averaging.” You will
need access code from Air Innovations service to
use in configuration 8 to reach configuration 10.

Jumper position 1

Jumper position 2

Jumper position 3

IMPORTANT

Wine Guardian cooling systems are supplied with 50 feet of 6 wire, Cat 3 twisted pair

communication cable with RJ11 type connectors. Caution must be taken when connecting

two lengths of communication cable (splicing) to ensure uniform wire color before and after

splice. An RJ11 Modular 6 wire STRAIGHT THROUGH type coupler is the ONLY coupler

approved for splicing Wine Guardian twisted pair communication cable.