Vetter pipe and test sealing bags – Vetter Pipe and Test Sealing Bags User Manual
Page 8

Truck compressed
air connection
Dummy coupling
Vetter Pipe and Test Sealing Bags
Page 8/33
3.2 Operation with controller, inflation hose
and other compressed air sources
Observe the maximum inlet pressure from the
compressed air source for the different
pressure levels (refer to the table below).
Applied pressure level
Maximum inlet pressure
of the compressed air source
0.5 bar
2 bar
1.0 bar
2 bar
1.5 bar
2 bar
2.5 bar
4 bar
Adapters in the adapter set
The adapter set contains adapters for the following air sources:
Truck compressed air connection and dummy coupling
Close the control line with the dummy coupling.
Local compressed air network
Connection on the output coupling of a compressed air network.
Truck tyre valve
For inflation with a normal hand pump or foot pump
Truck tyre valve connection
For taping off air from a spare wheel.
Hand pump and foot pump
Hand pump or foot pump with 2 m connection hose to the con-
nection onto the inlet coupling of a controller. Hand pump and
foot pump do not belong to the delivery package of the adapter
set.