Setting up a cli connection, Setting up a cli connection -5 – Carrier Access Adit 3104 User Manual
Page 45
![background image](/manuals/64095/45/background.png)
Adit 3104 - Release 1.6
4-5
Configuration
Setting up a CLI Connection
Setting up a CLI Connection
A CLI connection will require the LAN or WAN IP address of the unit. Note: If the WAN IP address
is used, the remote admin WAN access must be enabled with the following command sequence:
NOTE:
For Adit 3104 CLI commands see the Adit 3000 CLI Reference Manual. This is a
separate document and can be found on the CD that is provided with the product, or on the
Carrier Access customer website.
To connect with CLI, set up the connection:
If connecting via the Ethernet 100Base-T connection, use a Telnet TCP/IP program to access
the CLI. This requires an IP address of the unit.
Note: To display the current IP address of the unit, use the ifconfig command.
If connecting via RS-232, the port settings should be set to:
Bits per second: 115200 Data bits: 8
Parity: None Stop bits: 1
Flow control: None
Set your Terminal Emulation to: VT100
NOTE:
When using Tera Term (Telnet program) TCP/IP, CLI commands will not be
recognized until the following setup is completed.
In Tera Term go to Setup/Terminal
Set the New-line/Transmit value CR
Command
Description
Username: admin
Password: ********
Log into the system (username and password).
Adit 3104> enable
Enter the Privileged mode.
Password: ********
Enter password for the Privileged mode.
#configure terminal
Enter the Configuration mode.
(config)# remote-admin web
primary-port enable
Enable remote web admin.