Performance characteristics, Event response times – ThingMagic Micro Hardware User Manual
Page 68

Performance Characteristics
A D I V I S I O N O F T R I M B L E
Functionality of the Micro
63
Performance Characteristics
Event Response Times
The following table provides some metrics on how long common Micro operations take.
An event response time is defined as the maximum time from the end of a command (end
of the last bit in the serial stream) or event (e.g. power up) to the response event the
command or event causes.
Event Response Times
Start Command/
Event
End Event
Time
(msecs)
Notes
Power Up
Application Active (with
CRC check)
1500
This longer power up period should only
occur for the first boot with new firm-
ware.
Power Up
Application Active
120
Once the firmware CRC has been veri-
fied subsequent power ups do not
require the CRC check be performed,
saving time.
Tag Read
RF On
20
When in Power Mode = FULL
Tag Read
RF On
50
When in Power Mode = MINSAVE
Tag Read
RF On
120
When in Power Mode = SLEEP
Change to MINSAVE
PowerMode.MINSAVE
5
From Power Mode = FULL
Change to SLEEP
PowerMode.SLEEP
5
From Power Mode = FULL