Frequency hop table, Loads the, With the appropriate table for the selected region – ThingMagic Micro Hardware User Manual
Page 56: Regional frequency quantization

Regulatory Support
A D I V I S I O N O F T R I M B L E
Functionality of the Micro
51
Regional Frequency Quantization
When manually setting frequencies the module will round down for any value that is not
an even multiple of the supported frequency quantization.
For example: In the NA region, setting a frequency of 902,999 kHz results in a
setting of 902,750 kHz.
When setting the frequency of the module, any frequencies outside of the valid range for
the specified region are rejected.
Frequency Hop Table
The frequency hop table determines the frequencies used by the Micro when transmitting.
The hop table characteristics are:
Contains up to 62 slots.
Valid frequencies for the region currently selected.
Region
Frequency
Quantization
Minimum
Frequency
Maximum
Frequency
NA
250 kHz
902,000 kHz
928,000 kHz
EU3
100 kHz
865,600 kHz
867,600 kHz
IN
100 kHz
865,200 kHz
866,800 kHz
KR
25 kHz
910,000 kHz
914,000 kHz
KR2
25 kHz
917,000 kHz
923,500 kHz
PRC
250 kHz
920,125 kHz
924,875 kHz
CN
250 kHz
840,000 kHz
1
845,000 kHz
1
AU
250 kHz
920,750 kHz
925,250 kHz
NZ
250 kHz
922,250 kHz
927,250 kHz
JP
250 kHZ
916,800 kHz
920,800 kHz
Open
25 kHz
865,000 kHz
902,000 kHz
869,000 kHz
928,000 kHz
Note:
Micro