Page 29: View summed channels

background image

1) Program a function key to “ttl.rd”

(Total Remote Devices).

In this

example we’ll use

F2

for “ttl.rd”.

2) The current channel is displayed.

Press

F2 ttl.rd

to change the

display to the summed total.

3) The display briefly displays

“AddAll”. Then summed total
weight is displayed.

4) Subsequent presses of the

F2 ttl.rd

key will show all enabled

sum types.

TOTAL REM

DEVICES

See Function Key setup

on page 15.

kg

lb

M

kN

Ton

$GG$O

View Summed Channels

MOMENTARY

TOTAL REM

DEVICES

3DLU

TOTAL REM

DEVICES

3DLU

MOMENTARY

MOMENTARY

kg

lb

M

kN

Ton

kg

lb

M

kN

Ton

kg

lb

M

kN

Ton

F2

F2

F2

COMM Set Up 25

Figure 5-5. View Summed Channels

5.5 Behavior Of Zero And Tare In Multiple Channel Systems

Whatever channel that is displayed is considered the “Focus Channel.” Pressing the

ZERO

or

TARE

keys will only affect the displayed channel. When displaying summed channels,

zero and TARE commands will be sent to all devices that contribute to the displayed

weight. For example, if in the “BOTH” mode, and you are displaying Pair 1 (the sum of

SC0 and SC1), pressing

ZERO

will zero only SC0 and SC1. If displaying the grand total

using the ALL mode, then pressing

ZERO

will zero all connected sensors.

Using the TARE function: If one device is tared in the individual display mode, the

summed weight will be the sum of a Net weight and a Gross weight. If the TARE key is

pressed when displaying any of the summed modes, all devices that add to form the

current display are Tared and placed in Net mode.

5.6 Printer Set Up

The RS 232 Comm Port is capable of outputting tension data. All the weight modes the RF

linked weight device can measure are available in user formatted form. The control Mode

programs are what cause the MSI-8000 to print.
The modes are:

1. Assigned F-Key is pressed, one transmission of the selected string type is output.

2. On Load - When the tension on the link is stable, one transmission will output. Then

the tension must return to zero to enable another print output.

3. Continuous - Program the interval in seconds up to 65,535 seconds. Setting the

interval to 0 will set an interval as fast as the system can go. To disable printing set

the control mode to “OFF.”

The Comm Port settings are independent of any print settings in connected scales. They

reside only in the MSI-8000.