COMM Set Up 19

5.0

COMM Set Up

The MSI-8000 uses 802.15.4 transceivers to communicate between MSI’s Dyna-Links and

Crane Scales.
802.15.4 operates in the 2.4GHz systems if:

• Caution is taken to isolate antennas at least 10 feet (3 meters) from the MSI-8000

equipment.

MSI-8000 based RF systems are peer to peer. For multiple scale connections, the MSI-

8000 acts as the network coordinator.

The MSI-8000 uses three numbers to establish a piconet:

ScaleCore ID - This number is used to uniquely identify each device in a Piconet. It

has a range of 0-254 and must not be duplicated within the same RF Channel. For the
MSI-8000 as network coordinator, MSI recommends a number from 20-30.

RF Channel - Establishes the base network that all interconnected devices must

match. This number must be in the range of 12-23.

Network ID - This is a 64 bit number that all interconnected devices must match. The

MSI-8000 limits this number to a max of 6 digits for a range of 0-99999. Do not use a

small number here to help avoid other 802.15.4 networks that default to a Network ID

of 0.

For all devices that must interconnect, the RF Channel and Network ID must match. The

ScaleCore ID must be unique. The Dyna-Link or Crane Scale that is the weight source

should be set to a ScaleCoreID of 0. Then if other slave devices are added, they can be

added in sequence. The MSI-8000 ID is recommended to be in the range of 20-30.