6 weighvault, 1 demo setup of counterpart and weighvault, Demo setup of counterpart and weighvault – Rice Lake Counterpart Configurable Counting Indicator - User Manual Rev. D - Version 2.4 User Manual
Page 71

Scale Operations
65
8. To download the ID to Counterpart, connect Revolution, and select
Communications
and either Download
Configuration or Download Section.
9. All register IDs are now entered and available through Revolution.
Note
By uploading IDs using Revolution and saving them to a file the IDs can be backed up for future use.
5.6
WeighVault
WeighVault is a PC program that allows Counterpart users to add, edit, and access IDs over a network connection.
WeighVault surpasses the Counterpart's 150 ID limitation and eliminates front-panel entry of ID parameters.
In
and
Out
softkeys can be used to update the ID quantity with inventory changes. Setting up softkeys is explained in
Section 1.7 on page 5. If WeighVault is enabled the inventory changes are also sent to the WeighVault PC.
It also collects data as transactions occur, and provides detailed transaction and productivity reports that can be
exported to Excel, Word, or PDF. For WeighVault to function, the following criteria must be met:
•
Use onboard Ethernet or wireless option (PN72117 Ethernet TCP/IP Interface Installation and
Configuration Manual)
•
IP address assigned to the Counterpart (Refer to PN72117 Ethernet TCP/IP Interface Installation and
Configuration Manual)
•
WeighVault enabled in the Counterpart menu (ETHERNET menu; see Section 3.7.3 on page 42). Table 5-
1 lists parameters that must be entered in order for WeighVault to work.
Table 5-1. WeighVault Default Settings
Parameter
Default
DHCP
Consult with network administrator
IP ADDRESS
Consult with network administrator
NET MASK
Consult with network administrator
PORT
Port 10001
REMOTE IP
IP address of computer running WeighVault — must be static
REMOTE PT
5466
VAULT
Onboard or external if using a wireless option
Note
These default settings apply only if the VAULT parameter is set to ONBOARD. See Figure 3-22 on page 51.
5.6.1
Demo Setup of Counterpart and WeighVault
Install WeighVault. There are two setup programs that need to be installed.
On the PC
This setup was completed in Windows 7, however the basic information about setup is applicable to other
computer operating systems.
Use the following steps to set up WeighVault on the computer side.
1. Plug in crossover cable. The computer should be able to identify this cable.
2. Go to Properties, Internet Protocol, Version 4 - TCP/IPv4.
3. Choose Assign IP address.
4. Use the following IP address for this demo: 192.168.0.2 (if setting your system, check with your network
administrator).
5. Click on subnet mask field. This will fill screen in automatically.
6. Click OK and close each window.