3 advanced calibration – Rice Lake Combination System - Precision Loads PL9700 Indicator User Manual
Page 10

6
PL9700 Installation Manual
2. To enter the truck’s loaded weight, press the
Up
or
Down
key until the information display
shows Calibrate Channel 1.
3. Press the
Full
softkey. The information display
will briefly show LOAD Channel 1 before
Calibrate Full weight. It will then show Set
Ch-1 Full Weight.
4. The last number of the weight display will be
flashing, telling you that number is ready to
be changed. To change the number’s value,
press the
Up
or
Down
key. To select a different
number, press the
left arrow
or
right arrow
softkey.
5. When the number on the weight display
matches your truck (channel 1) loaded weight,
press the
Enter
softkey to store the weight in
the indicator’s memory.
The information display will briefly show
Store Ch-1 full weight and then return to Setup
selection and the weight display will show
Setup.
6. To enter the trailer’s loaded weight, press the
Up
or
Down
key until the information display
shows Calibrate Channel 2.
7. Press the
Full
softkey.
The information display will briefly show
LOAD Channel 2 before Calibrate Full
weight.
It will then show Set Ch-2 Full Weight.
8. The last number of the weight display will be
flashing, telling you that number is ready to
be changed. To change the number’s value,
press the
Up
or
Down
key. To select a different
number, press the
left arrow
or
right arrow
softkey.
9. When the number on the weight display
matches your trailer’s (channel 2) loaded
weight, press the
Enter
softkey to store the
weight in the indicator’s memory.
The information display will show Store Ch-2
full weight then return to Setup selection.
At any time, you can exit the calibration process by
pressing the
Cancel
softkey.
T h e i n f o r m a t i o n d i s p l a y w i l l b r i e f l y s h o w
CANCEL-Setup.
3.3
Advanced Calibration
Another way to enter the loaded weight into the
indicator is with the advanced calibration feature. This
method allows the calibration of several trucks to be
centrally controlled. The driver does not have to enter
the setup mode of the indicator, even for calibration.
After setting in the tare weight, the driver need only
record two sets of numbers:
•
The truck and trailer loaded weight shown by
the platform scale.
•
The channel 1 and channel 2 weights recorded
on the
PL9700
while the truck is on the
platform scale.
The following steps are used for the advanced
calibration, which can be done on an empty truck, if
necessary.
1. Press the
Menu
key for 5 seconds until the
information display shows Setup Menu.
After releasing the
Menu
key, the information
display will show Setup selection and the
weight display will show Setup.
2. Press the
Up
or
Down
key until the
information display shows Set Advanced
calibration.
3. Select the channel to calibrate by pressing the
CH-1
softkey or the
CH-2
softkey.
NOTE: For this example, we will assume you selected CH-1.
4. Enter the number that was earlier recorded as
the number shown on the indicator’s weight
display for channel 1 while sitting on the
platform scale. Change the numbers in the
same manner as then setting the original
loaded-weight calibration. See “Entering the
Loaded Weight” on page 5. Press the
Enter
softkey when completed.
5. The information display will show
Enter Ch. 1
Legal weight
.
6. Enter the number that was earlier recorded as
the legal truck weight from the platform scale.
Change the numbers in the same manner as in
Step 4, above.
7. Press the
Enter
softkey when completed.
The information display will show Setup
selection.
8. Press the
Cancel
softkey to return to normal
operation.