Rice Lake 920i Installation Manual V3.08 User Manual
Page 47

Configuration
41
CONTACT
—
Allows specification of contact information for use in
iQUBE
alert messages. See Level 3
submenu descriptions in Table 3-8 on page 42.
LOCALE
OFF
ON
Locale. Set this parameter ON to enable the LATUDE and ELEVAT parameters. Specifying
latitude and elevation of the scale site provides compensation for gravitational effects.
Attached scales must be recalibrated after changing this parameter from OFF to ON.
NOTE: Gravitational compensation settings do not affect
iQUBE
scales.
LATUDE
45
0–90
Latitude. Specify the latitude of the scale site in degrees. This parameter is shown only if
LOCALE=ON.
ELEVAT
345
±0–9999
Elevation. Specify the elevation of the scale site in meters. Valid values are –9999 through
9999. This parameter is shown only if LOCALE=ON.
IMAGE
NEGATIVE
POSITIVE
Specifies whether the indicator display is presented as blue-on-white or white-on-blue.
The default value, NEGATIVE, shows the standard blue-on-white image when using the
stock LCD display; the optional outdoor display shows white-on-blue. When using the
outdoor display, set this value to POSITIVE to show the standard, blue-on-white display
image, then use the LCD contrast potentiometer to adjust for optimal viewing.
LANGUAGE
ENGLISH
language
Specifies the language and character set used for
920i
prompts and printing.
Level 3 submenus
DATEFMT
MMDDYYYY
DDMMYYYY
YYYYMMDD
YYYYDDMM
Specifies the format used to display or print the date.
DATESEP
SLASH
DASH
SEMI
Specifies the date separator character.
TIMEFMT
12HOUR
24HOUR
Specifies the format used to display or print the time.
TIMESEP
COLON
COMMA
Specifies the time separator character.
FEATURE Menu
Parameter
Choices
Description
Table 3-7. FEATURE Menu Parameters (Continued)