The default A/D sample rate (SMPRAT
parameter on the SCALES menu) has been
changed from 120 to 30 Hz.
•
The KEXIT command has been removed and
r e p l a c e d w i t h K S AV E E X I T. ( S e e
Section Table 9-1. on page 85.)
•
Error codes returned on the XE serial
command have been updated (see Table 10-3
Version 3.05-3.06
•
Support for local/remote indicator configurations
provides function equivalent to a legal-for-trade
remote display with keypad for truck scale and
similar applications. See Section 10.5 on
page 107 for more information.
•
The description for setting rate of change (ROC)
parameters has been changed. See Table 3-3 on
page 27 for details.
•
New values have been added to the STREAM
parameter on the SERIAL menu to allow
streaming of keypad events to another indicator
(4KEYS, KEYPAD) and, for the local/remote
function, to send the complete display image
(DISPLAY). See Section 3.2.2 for more
information.
•
Reprinting of any previous print transaction is
now supported by the alibi feature. The feature is
enabled using the ALIBI parameter on the
FEATURE menu; print transactions can be
recalled by assigning an
Alibi
softkey, also
configured using the FEATURE menu (see
•
New IMAGE parameter on the FEATURE menu
allows inversion of the display image
(blue-on-white or white-on-blue) for support of
the outdoor display option. See Section 3.2.3.
•
Display and printing of audit trail information is
described in Section 10.11 on page 117.
Version 3.00
•
The desktop model of the
920i
has been
discontinued. Drawings and parts lists for the
desktop model have been removed from this
manual.
•
Added support for multi-range and
multi-interval scale configurations.
•
Zero tracking, zero range, and motion band
parameters (SCALES menu) have been
changed to allow numeric values.
•
Added peak hold function to SCALES menu.
•
Added last zero and temporary zero functions
to calibration menus to allow recalibration
based on previous zero values.
•
Enhanced print formatting with addition of
audit format and twenty auxiliary formats.
•
The SERIAL menu has been restructured to
provide additional parameters for configuring
RS-485 communications. See Figure 3-10 on
•
A new digital input count (DINCNT) setpoint,
used to count digital input pulses, has been
added to the supported setpoint kinds. See
•
A SENSE parameter has been added to
optionally invert the value of setpoint digital
outputs. See Section 8.0 on page 66.
•
TRIGGER (digital output trigger) has been
added as a selection under the DIG I/O menu
(see Section 3.2.6 on page 46) for custom
applications.
•
Support has been added for EtherNet/IP and
analog input/thermocouple option cards.