5 summary of changes – Rice Lake 920i Installation Manual V3.08 User Manual
Page 11

Introduction
5
Option Cards
Table 1-4 lists the available
920i
option cards. Any of
the listed option cards can be installed in Slot 2 of the
CPU board or in any available slot of an attached
expansion board.
Expansion Boards
Table 1-5 lists the expansion boards available for the
panel mount and wall mount enclosures. The panel
mount enclosure can accommodate a single 2-card
expansion board; the wall mount enclosure supports
either a 2-card or a 6-card expansion board. Any of
the available option cards can be installed in any
available expansion board slot.
A second two- or six-card expansion board can also be
connected to the
920i
, providing up to 14 option card
slots. Consult factory for details. See Section 2.5 on
page 12 for detailed information about slot and serial
port assignments for expanded system configurations.
Relay Options
8-, 16-, and 24-channel relay racks are available for all
920i
systems. Relays can be installed internally in the
wall mount enclosure; all other models require an
external enclosure for the relays. Consult factory for
details.
DC Power Supplies
Two DC power supplies are available for mobile
920i
applications:
PN 97474, 9–36 VDC supply
PN 99480, 10–60 VDC supply
Consult factory for more information.
Outdoor Display
An optional display, PN 100759, is available for
applications requiring use of the
920i
in bright, sunlit
environments. Consult factory for details.
1.5
Summary of Changes
Changes to recent editions of this manual are listed
below:
Version 3.08
•
A new value, KBDPRG, on the Port 2 serial
menu allows keyboard scans to be passed
directly to an
i R i t e
user program (see
•
Support for negative tracking has been added
to the ALGOUT menu (see Section 3.2.7 on
•
A new stream token, Z, has been added to the
stream format status identifiers to
indicate center-of-zero (see Table 10-8 on
page 108).
Version 3.07
•
Support has been added for the dual-channel
analog output card (PN 103138) and the
ControlNet interface card (PN 103136).
•
New OVRBASE parameter, on the
REGULAT submenu of the FEATURE menu,
allows specification of calibrated or scale zero
as the base for overload calculation. See
page 43 for more information.
•
A new top-level menu, FLDBUS, is now
shown if a DeviceNet, Profibus, EtherNet/IP,
or ControlNet is installed.The two parameters
u n d e r t h e FL D B U S m e n u a l l o w b y t e
swapping to be enabled (SWAP parameter)
and for the transfer size of the swapped bytes
t o b e s p e c i f i e d ( D ATA S I Z E ) . S e e
S e c t i o n 3 . 2 . 8 o n p a g e 4 9 f o r m o r e
information.
Option Card
PN
Single-channel A/D card
68532
Dual-channel A/D card
68533
Single-channel analog output card
67602
Dual-channel analog output card
103138
Dual serial port expansion card
67604
24-channel digital I/O expansion card
67601
1MB NV RAM memory expansion card
67600
Pulse input card
67603
Ethernet communications card
71986
EtherNet/IP interface card
87803
DeviceNet interface card
68541
Allen-Bradley Remote I/O interface card
68539
Profibus DP interface card
68540
ControlNet interface card
103136
Analog input card with thermocouple input
87697
Table 1-4. Part Numbers for 920i Option Cards
Expansion Board
PN
Two-card expansion board for panel mount
enclosure, slots 3–4. Includes 2-inch, 34-pin
ribbon cable and power supply cable.
71743
Two-card expansion board for wall mount
enclosure, slots 3–4. Includes 24-inch, 34-pin
ribbon cable and power supply cable.
69782
Six-card expansion board for wall mount
enclosure, slots 3–8. Includes 16-inch, 34-pin
ribbon cable and power supply cable.
69783
Table 1-5. Part Numbers for 920i Expansion Boards