6 batching control commands, Batching control commands – Rice Lake 920i Installation Manual V3.05 User Manual
Page 99

Serial Commands
93
9.1.6
Batching Control Commands
The commands listed in Table 9-12 provide batching control through the serial port.
XA#n
Transmit accumulator value in displayed units
nnnnnn UU
XAP#n
Transmit accumulator value in primary units
XAS#n
Transmit accumulator value in secondary units
XAT#n
Transmit accumulator value in tertiary units
XG#n
Transmit gross weight in displayed units
nnnnnn UU
XGP#n
Transmit gross weight in primary units
XGS#n
Transmit gross weight in secondary units
XGT#n
Transmit gross weight in tertiary units
XN#n
Transmit net weight in displayed units
nnnnnn UU
XNP#n
Transmit net weight in primary units
XNS#n
Transmit net weight in secondary units
XNT#n
Transmit net weight in tertiary units
XT#n
Transmit tare weight in displayed units
nnnnnn UU
XTP#n
Transmit tare weight in primary units
XTS#n
Transmit tare weight in secondary units
XTT#n
Transmit tare weight in tertiary units
XE
Query system error conditions
nnnnn
See Section 10.1.4 on page 103 for detailed information
about the XE command response format.
Command
Description
Values
BATSTART
Batch start
If the BATRUN digital input is active (low) or not assigned, the BATSTART
command can be used to start the batch program.
BATSTOP
Batch stop
Stops the batch program and turns off all associated digital outputs.
BATPAUSE
Batch pause
Stops the batch program at the current step. All digital outputs set on by the
current step (except for those set by concur setpoints) are set off. The BATSTRT
DIGIN, BATSTART serial command, Batch Start softkey, or the StartBatch
function in an
iRite
program can be used to restart the batch program at the
current step.
BATRESET
Batch reset
Stops the program and resets the batch program to the first batch step. Run the
BATRESET command after making changes to the batch configuration.
Table 9-12. Batching Control Commands
Command
Description
Values
Table 9-11. Normal Mode Serial Commands