13 zero tolerance weight, 14 modifying the discharge option, E section 3.13 – Rice Lake 920i FlexWeigh Systems - 201/202 User Manual
Page 24

20
3.13 Zero Tolerance Weight
The weight under which the system considers the scale to be empty and allow a new batch to begin.
Note
If a password is in the system, see Section 3.4 to enter the setup menu.
Prior to entering a new value, the existing value needs to first be cleared by using the clear key.
1. From the main setup menu screen, press
More=>
twice to access the third menu screen.
2. Press
Zero Toler Weight
.
Enter Zero Tolerance Weight
=> 110.00
08/27/2012
02:15PM
SCALE #1
000.0
SCALE
#1
Gross
Lb
Target
Dribble
Preact
Ingredient Name
0.50 lb
0.00 lb
0.04 lb
Ingredient 1
Consecutive Nbr
Near Zero
Formula Name
Batch Total
9
0.04 lb
Grout
0.00 lb
Home
Exit
Cancel
Figure 3-14. Enter Zero Tolerance Weight
3. Enter the zero tolerance weight using the numeric keypad.
4. Press
Enter
save value.
3.14 Modifying the Discharge Option
Note
If a password is in the system, see Section 3.4 to enter the setup menu.
Prior to entering a new value, the existing value needs to first be cleared by using the clear key.
1. From the main setup menu screen, press
More=>
four times to access the next menu screen.
2. Press
Discharge Option
.
3. Press
Discharge Enabled
or
Discharge Disabled
. System will toggle between the two modes of operation:
- Enabled: 920i System 202, system controlled discharge at batch complete.
- Disabled: 920i System 201, External provided method to empty scale at batch complete.