5. The system prompts
Enter Ingredient Name
. Enter the name and press
Enter
.
6. The system prompts
Enter Ingredient Preact
. Enter a value and press
Enter
.
Note
Note
Preact weight allows material to cut off prior to the original target value to allow for free fall material to settle
onto the scale.
Prior to entering new value, the existing value needs to be cleared by using the clear key.
7. Press
Enter
to save.
8. Press
Exit
to return to previous menu.
To enter alpha characters, press the Up Arrow to access a pop up an alphabetic screen. Use arrows to select
letters.
Use keypad to enter numeric values.
3.10.2 Add/Edit Formulas
1. From the main setup menu screen, press
More=>
to access the next menu screen (shown in Figure 3-5).
2. Press
Database Setup
.
3. Press
Add/Edit Formulas
.
4. The system prompts
Enter Formula ID
. Enter the ID and press
Enter
.
5. The system prompts
Enter Formula Name
. Enter the name and press
Enter
.
6. The system prompts
Enter Ingredient ID
. Enter a value and press
Enter
.
7. The system prompts
Enter Ingredient Target Weight
. Enter a value and press
Enter.
Note
Note
Target weight is the desired weight value for a final fill weight.
Prior to entering new value, the existing value needs to be cleared by using the clear key.
8. The system prompts
Enter Ingredient Dribble Weight
. Enter a value and press
Enter.
When a 2-speed fill is enabled (either Parallel or Sequential), Dribble Weight is the desired weight value below
the Target Weight that the cycle switches from Fast Feed to Dribble Feed.
Prior to entering new value, the existing value needs to be cleared by using the clear key.
9. The system prompts
Enter Ingredient Order
. Enter a value and press
Enter
.
10. The system prompts
More Ingredients.
Press
Yes
to add more ingredients or
No
to save and exit.
3.10.3 Delete Formulas
Removes selected formula from the database.
1. Press
Delete Formulas
.
2. Enter Formula ID, then press
Enter
to delete.
3.10.4 Exit
Press the
Exit
to return to previous menu.
3.11 Delay After Discharge
The delay allowed after discharge is complete before beginning a new batch. This allows the discharge gate to
close before new batch begins loading.
1. From the main setup screen, press
More =>
twice to access the third setup menu screen.
2. Press
Delay After Disch.