3.1 Displayed Error Messages
The
880
provides a number of front panel error messages to assist in problem
diagnosis. Table 3-1 lists these messages and their meanings.
Error
Message
Description
Solution
¯ ¯ ¯ ¯
¯ ¯
Over range
Check for improper load cell
wiring, configuration,
calibration, scale hardware
problems.
_ _ _ _
_ _
Under range
(center
dashes)
A/D out of range
Or if using local/remote (serial scale) -
loss of serial scale data.
CFGERR
Configuration error on power up if there
was an error loading configuration
Press the Enter key to reboot
the indicator.
ERROR
Internal program error
Check configuration.
HWFERR
Hardware failure error
• on failure to write to the EEPROM
• any error (except for a battery error or
an accumulation over range error)
when exiting the menu
Press the Enter key to reboot
the indicator.
LOBATT
The low battery error flashes every 30
seconds when the battery is low.
Replace the battery.
NOTARE
Tare is prevented because of
regulatory mode settings, the
configuration of the TAREFN
parameter, motion on the scale, etc.
Change regulatory mode
settings or the TAREFN
parameter.
RANGE
A numeric value entered in
configuration is out of the acceptable
range. The error is displayed
momentarily – then parameter being
edited is displayed so the value can be
corrected.
Re-enter a value that is in
range for the parameter being
edited.
NO ZERO
Zero is prevented (due to regulatory
mode settings, motion on the scale,
zero range settings)
Check zero settings and for
motion.
Table 3-1.
880