6 preset tare (keyed tare), 7 print ticket, 8 front panel setup – Rice Lake 880 Performance Series Indicator/Controller Operators Manual User Manual
Page 11: 9 displaying audit trail information, Preset tare (keyed tare), Print ticket, Front panel setup, Displaying audit trail information

7
880 Operator’s Manual
1.4.6
Preset Tare (Keyed Tare)
Tare mode must be set to keyed or both for preset tare to function.
1. With the scale empty and zero weight on the display, press
.
2. Display will show (000000); the focused digit will flash.
3. To edit the value:
• Press or to select the digit.
• Press
or
to
increment or decrement the value.
• Press
to move to the decimal point entry.
• Press or to adjust the decimal point placement.
• Press
when the value is correct.
4. The display will change to the Net mode and the
PT
LED lights to show the
preset tare was entered.
Entering a keyed tare of zero will remove the stored tare value.
1.4.7
Print Ticket
1. Wait for the (
) LED to light.
2. Press
to send data to a communications port.
1.4.8
Front Panel Setup
1. Press
to enter user setup mode. Use user setup to:
• View audit trail information
• Enter setup mode if audit trail is enabled
• View or set time and date
• View or clear the accumulator
• Change setpoint values and enable/disable setpoints
• View the current tare value
1.4.9
Displaying Audit Trail Information
The Audit Trail Configuration and Calibration counters can be viewed through the
User Menu.
1. Press ,
AUDIT
is displayed.
2. Press to display the Legally Relevant Firmware version.
3. Press
to
display
CALIB
.
4. Press to view the Calibration Counter.
5. Press
to return to
CALIB
.
6. Press
to
display
CFG
.
7. Press to view the Configuration Counter.
Note
TARE
TARE
TARE
Note
MENU
MENU
MENU