4 controlnet interface specifications – Rice Lake 920i Programmable HMI Indicator/Controller - ControlNet Interface User Manual
Page 20

16
ControlNet Installation and Programming Manual
4.4
ControlNet Interface Specifications
Power Requirements
Bus Adapter Card with ControlNet Module, DC Power:
Supply voltage: 6 VDC, supplied by indicator bus
Typical current draw: 350 mA
Power consumption: 2.1 W
Indicators, Typical AC Load:
520
Power (TRMS):
3.51 W
Current (TRMS):
33.7 mA
820i
Power (TRMS):
2.18 W
Current (TRMS): 28.9mA
920i
Power (TRMS):
2.18 W
Current (TRMS):
28.9 mA
Communications Specifications
ControlNet RG-6 quad-shielded coaxial cable
Update rate is dependent on the configured baud rate and the
number of network nodes. Maximum update rate is 20–24 per
second.
Environmental Specifications
Temperature:
–10° to +40° C (14° to 104° F)
Conformance
The ControlNet Interface has been tested for conformance to
ControlNet communications adapter profile 12.
0007
B3:4
0
Swap Word 1
SWP
Swap
Source
#N7:4
Length
1
SWP
Word 1 Input I:9.5
0008
B3:4
1
Swap Word 2
SWP
Swap
Source
#N7:5
Length
1
SWP
Word 2 Input I:9.6
0009
B3:4
2
Swap Word 3
SWP
Swap
Source
#N7:6
Length
1
SWP
Word 3 Input I:9.7
0010
B3:4
3
Swap Word 4
SWP
Swap
Source
#N7:7
Length
1
SWP
Word 4 Input I:9.8
0011
END