Kontron KBox A-101 Users Guide User Manual
Page 17

7. Product Description
KBox A-101 – User’s Guide (Version 1.00)
Termination Resistor for RS422 and RS485
SW1 Settings
DIP4
Deactivated
OFF
Activated
ON
DIP4 setting in order to activate or deactivate the termination resistor for RS422 and RS485
Timeout
Min. Baud Rate
SW1 Settings
DIP5
DIP6
DIP7
DIP8
10.2ms
1200
OFF
OFF
OFF
OFF
9.6ms
OFF
OFF
OFF
ON
9.0ms
OFF
OFF
ON
OFF
8.4ms
OFF
OFF
ON
ON
7.8ms
OFF
ON
OFF
OFF
7.2ms
OFF
ON
OFF
ON
6.5ms
OFF
ON
ON
OFF
5.9ms
OFF
ON
ON
ON
4.8ms
2400
ON
OFF
OFF
OFF
4.3ms
ON
OFF
OFF
ON
3.7ms
ON
OFF
ON
OFF
3.1ms
ON
OFF
ON
ON
2.5ms
4800
ON
ON
OFF
OFF
1.9ms
ON
ON
OFF
ON
1.2ms
9600
ON
ON
ON
OFF
0.6ms
19200
ON
ON
ON
ON
DIP5, DIP6, DIP7 and DIP8 settings in order to set the needed timeout and min. baud rate
7.1.4.2.
DIP-Switch Settings (SW1) for LPCtoCAN Adapter
The DIP-switch is for setting the SJA1000-base address, the SJA-interrupt, and the NVRAM operation mode.
Default setting
Color marking: Default setting for KBox A-101 in the following tables
www.kontron.com
15