COMX Console Redirection Settings
Feature
Options
Description
Terminal Type
VT100
VT100+
VT-UTF8
ANSI
Emulation: ANSI: Extendet ASCII char set. VT100: ASCII char
set. VT100+: Extends VT100 to support color, function keys,
etc. VT-UTF8: Uses UTF8 encoding to map Unicode chars
Bits per second
9600
19200
38400
57600
115200
Selects serial port transmission speed. The speed must be
matched on the other side. Long or noisy lines ma require
lower speeds.
Data Bits
7
8
Data Bits
Parity
None
Even
Odd
Mark
Space
A parity bit can be sent with the data bits to detect some
transmission errors.
Stop Bits
1
2
Stop bits indicate the end of a serial data packet. (A start bit
indicates the beginning). The standard setting is 1 stop bit.
Communication with slow devices may require more than 1.
Flow Control
None
Hardware RTS/CTS
Flow control can prevent data loss form buffer overflow.