Amp power input – x2/x3, Lvds interface, 11 amp power input – x2/x3 – Kontron MSM-LP Manual User Guide V106 User Manual
Page 21: 12 lvds interface, Fpc connector – x11

MSM-LP / MSM-LP Connectors & Jumpers
www.kontron.com
17
3.2.11 AMP Power Input – X2/X3
The AMP power inputs are always connected on the top side of the board.
Header
Nr.
Signal Name
Function
AMP 2.8mm
X3
V5.0_IN
5 Volt power IN
Header
Nr.
Signal Name
Function
AMP 4.75mm
X2
GND
Ground
X2 and X3 not equipped on system board.
3.2.12 LVDS Interface
The LVDS implementation complies with the JILI specification of Kontron (JILI30). When using an LCD, additional
voltages may be required to drive the display logic and supply the backlight converter therefore an additional
connector for supply voltages is provided.
The FPC connector is only mounted on the top side. The corresponding backlight connector is assembled on the
opposite side.
FPC Connector – X11
Header
Pin
Signal Name
Function
Pin
Signal Name
Function
1
FPC_AN
First channel data out A
16
NC
Not connected
2
FPC_AP
First channel data out A
17
GND
Ground
3
FPC_BN
First channel data out B
18
NC
Not connected
4
FPC_BP
First channel data out B
19
NC
Not connected
5
FPC_CN
First channel data out C
20
NC
Not connected
6
FPC_CP
First channel data out C
21
NC
Not connected
7
GND
Ground
22
NC
Not connected
8
FPC_CLKN
First channel clock
23
NC
Not connected
9
FPC_CLKP
First channel clock
24
GND
Ground
10
FPC_DN
First channel data out D
25
SDA
I2C data line
11
FPC_DP
First channel data out D
26
DATAENA
Panel power output
12
NC
Not connected
27
SCL
I2C clock line
13
NC
Not connected
28
VCC
+3.3V power *)
14
GND
Ground
29
VCC
+3.3V power *)
15
NC
Not connected
30
VCC
+3.3V power *)
*) Panel power can be set to +5V by assembly option.