Indexed register map of watchdog device 08h, Register attributes – Kontron MSM-LP Manual User Guide V106 User Manual
Page 30
MSM-LP / Special Features
www.kontron.com
26
Indexed Register Map of Watchdog Device 08h
Index
Bit
Name
Access
Function
0x30
0
WDT_EN
RW
Watchdog device enable register: 0=disable,1=enable
0x30
1-7
RsvdP
Reserved
0xF0
0
WDT_EVENT
RO
0: no time out has occurred
1: time out has occurred
Writing "1" to this bit will clear the status
0xF0
1-2
WDT_UNIT
RW
00: Timer Unit is 10ms
01: Timer Unit is 1 second
10: Timer Unit is 1 minute
11: reserved
0xF0
3-7
RsvdP
Reserved
0xF1
7-0
WDT_CNT
RW
The number of time units for the watchdog timer.
Write the same non-zero value twice to enable the timer; otherwise the timer is
disabled.
Register Attributes
Attribute
Description
RsvdP
RESERVED AND PRESERVED
Reserved for future RW implementations. Registers are Read-only and the software must preserve the value for
writes to this bit.
RW
READ-WRITE REGISTER
Register bits are Read-Write and can be set or cleared by software.
RO
READ-ONLY
Register bits are Read-only and can not be altered by software.
WO
WRITE-ONLY
Register bits can only be Written. Reading returns indeterminable data.