9 com port configuration sub-menu – Kontron AT8060 User Manual
Page 98
Software Setup
83
www.kontron.com
5.1.4.9
COM Port Configuration sub-menu
Device power-up delay
Auto, Manual
Maximum time the
device will take before it
properly reports itself to
the Host Controller.
'Auto' uses default
value: for a Root port it
is 100 ms, for a Hub port
the delay is taken from
Hub descriptor.
Device power-up delay in
seconds
Numeric
Delay range is 1..40
seconds, in one second
increments
Mass Storage Devices:
Display only
USB Device X
Auto, Floppy, Forced
FDD, Hard Disk, CD-
ROM
Available on detected device
Mass storage device
emulation type. 'AUTO'
enumerates devices
according to their media
format. Optical drives
are emulated as
'CDROM', drives with no
media will be emulated
according to a drive
type.
Feature
Option
Description
Help text
COM Port Configuration
Subtitle
COM Port Chip
Display only
COM Port Parameters.
COM Port A Configuration
Selects sub-menu.
Set Parameters of COM
port A
COM Port B Configuration
Selects sub-menu.
Set Parameters of COM
port B
Feature
Option
Description
Help text