beautypg.com

Kontron AT8060 User Manual

Page 60

background image

45

AT8060

www.kontron.com

26

FRU2+ RTM Power

Threshold

FRU 2 (RTM) + FRU 3 (RTM's disk 1) + FRU 4 (RTM's disk 2)
Power consumption in watts
Sensor type = 0Bh Other Unit-Based Sensor (Watt)
Event Reading type code = 01h threshold base
See IPMI v2.0 table 42-2 for threshold based event

27

Vcc -48V Feed

Threshold

Voltage on -48v feed board input power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event

28

Vcc +12V SUS

Threshold

Voltage on 12V suspend (management) power supply
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event

29

Vcc +5V SUS

Threshold

Voltage on board 5.0V suspend (management) power supply
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event

30

Vcc +3.3V SUS

Threshold

Voltage on board 3.3V suspend (management) power supply

(Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event

31

Vcc +1.8V SUS

Threshold

Voltage on board 1.8V suspend (management) power supply

(Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event

32

Vcc +1.5V SUS

Threshold

Voltage on board 1.5V suspend (management) power supply

(Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event

33

Vcc +1.25V SUS

Threshold

Voltage on board 1.25V suspend (management) power supply

(Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event