Kontron AT8060 User Manual
Page 60
45
www.kontron.com
26
FRU2+ RTM Power
Threshold
FRU 2 (RTM) + FRU 3 (RTM's disk 1) + FRU 4 (RTM's disk 2)
Power consumption in watts
Sensor type = 0Bh Other Unit-Based Sensor (Watt)
Event Reading type code = 01h threshold base
See IPMI v2.0 table 42-2 for threshold based event
27
Vcc -48V Feed
Threshold
Voltage on -48v feed board input power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event
28
Vcc +12V SUS
Threshold
Voltage on 12V suspend (management) power supply
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event
29
Vcc +5V SUS
Threshold
Voltage on board 5.0V suspend (management) power supply
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event
30
Vcc +3.3V SUS
Threshold
Voltage on board 3.3V suspend (management) power supply
(Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event
31
Vcc +1.8V SUS
Threshold
Voltage on board 1.8V suspend (management) power supply
(Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event
32
Vcc +1.5V SUS
Threshold
Voltage on board 1.5V suspend (management) power supply
(Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event
33
Vcc +1.25V SUS
Threshold
Voltage on board 1.25V suspend (management) power supply
(Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event