beautypg.com

Kontron AT8060 User Manual

Page 63

background image

48

AT8060

www.kontron.com

52

Power State

Discrete

Board Power State
Sensor type = D0h Kontron OEM Power State Sensor
Event Reading type code = 6Fh Sensor specific
See OEM sensor table, Sensor type code D1h for sensor definition

53

Power Good

Discrete

Actual power good status
Sensor type = 08h Power Supply
Event Reading type code = 77h OEM
See OEM sensor table, Event/Reading type code 77h for sensor

definition

54

Power Good Event

Discrete

Power good status event that occur since the last power on or

reset
Sensor type = 08h Power Supply
Event Reading type code = 77h OEM
See OEM sensor table, Event/Reading type code 77h for sensor

definition

55

Board Reset

Discrete

Board reset type and sources
Sensor type = CFh OEM (Kontron Reset Sensor)
Event Reading type code = 03h Digital Discrete
Only offset 0,1 are used
See OEM sensor table, Sensor type code CFh for sensor definition

56

POST Value

Discrete

Show current postcode value. No event generated by this sensor
Sensor type = C6h OEM (Kontron POST value sensor)
Event Reading type code = 6Fh Sensor specific
Only offset 0 to 7 and 14 are used
See OEM sensor table, Sensor type code C6h for sensor definition

57

Memory Err

Discrete

Memory Error
Sensor type = 0Ch Memory
Event Reading type code = 6Fh Sensor specific
Only offset 0,1,7 are used
See IPMI v2.0 table 42-3, Sensor type code 0Ch for sensor

definition