beautypg.com

Cp371 introduction – Kontron CP371 User Manual

Page 27

background image

CP371

Introduction

ID 23762, Rev. 02

© 2002 PEP Modular Computers GmbH

Page 1 - 11

Note:

PRODUCTION ACCURACY 1: calibration by PEP; single samples

PRODUCTION ACCURACY 2: best case calibration (not supported by PEP); mean average

of samples (sample count > 100)

Table 1-5: CP371 Accuracy

INPUT

TYPE

and

RANGE

SIGNAL ACCURACY

at 23°C

± % of

FULL SCALE

ACCUMULATING

DEVIATION

% per K

(S and E1 BOARDS

ACCUMULATING

DEVIATION

% per K

(E2 BOARDS

BASIC AC

CURACY

0 V –

5 V

< 0.0488

< 0.0006

< 0.0006

0 V – 10 V

< 0.0244

< 0.0004

< 0.0004

- 5 V – + 5 V

< 0.0244

< 0.0004

< 0.0004

- 10 V – + 10 V

< 0.0244

< 0.0004

< 0.0004

0 mA – 20 mA

< 0.0488

< 0.0006

< 0.0006

BA

SIC A

CCURACY

(statistically evaluaated)

0 V –

5 V

< 0.0244

< 0.0004

< 0.0004

0 V – 10 V

< 0.0244

< 0.0004

< 0.0002

- 5 V – + 5 V

< 0.0244

< 0.0004

< 0.0002

- 10 V – + 10 V

< 0.0122

< 0.0002

< 0.0002

0 mA – 20 mA

< 0.0244

< 0.0004

< 0.0004

PRODUCTION

ACCURA

CY 1

VOLTAGE

< 0.15

< 0.001

< 0.001

CURRENT

< 0.15

< 0.001

< 0.001

PRODUCTION

ACCURAC

Y 2

VOLTAGE

< 0.25

< 0.001

< 0.001

CURRENT

< 0.25

< 0.001

< 0.001