Rear panel, Controls and functions – FBT MPU User Manual
Page 25
CAUTION
RISKOFELECTRICSHOCK
DONOTOPEN
TOREDUCETHERISKOFELECTRICSHOCKDONOT
REMOVECOVER(ORBACK)NOUSERSERVICEABLE
PARTSINSIDEREFERSERVICINGTOQUALIFIED
SERVICEPERSONNEL
MadeinItaly
MPU 4060
AMPLIFIER 1
AMPLIFIER 4
AMPLIFIER 3
AMPLIFIER 2
VOLUME
OUT
INPUT
H C S
VOLUME
OUT
INPUT
H C S
VOLUME
OUT
INPUT
H C S
VOLUME
OUT
INPUT
H C S
85÷132Vac / T3,15A-250V
170 ÷ 264 Vac / T1,6A-250V
Power Consumption 250VA
24
3
REAR PANEL
MPU 4240 / MPU 4120 / MPU 4060 / MPU 2120
6
7
8
9
7
8
9
7
8
9
7
8
9
[6] ALIMENTAZIONE
To change the supply voltage value see page 29
[7] INPUT:
[8] VOLUME:
: Socket for mains connection, system power switch and housing of
power circuit protection fuse. If the fuse breaks, it shall only be replaced by fuses with equal
electrical features.
Three-pin connectors with screw locking, they enable the connection of the
input signals of amplifiers 1/2/3/4.
Only use shielded cables avoiding unbalanced lines (otherwise, cables shall be as short as
possible).
Before changing input cables or connectors, turn the level controls of the amplifiers to the
minimum.
Adjustment of the output level of the amplifiers.
[9] OUT : Output connectors with two faston for connecting speakers with the 100V/ 70V line
transformer. Configurations in stereo or “sum”modeareavailable.
(see page 25-26-27-28)
UK