^FL (Fault, GET and SET)

GET format: ^FL;

RESPONSE format: ^FLcddddd; where c is a fault code and ddddd is an associated detail value.

SET format: ^FLC; to turn off the FAULT LED.

Fault Code

Name

Detail value

Description

N

None

# of power on events
since some other fault

No fault

A

Antenna Tuner Match

Best SWR * 10. (999 is
interpreted as 99.9:1
SWR)

NO TUNE
ATU could not find an
acceptable match for
antenna

C

Drain Current

Current in tenths of an
Ampere. See ^PC

HI CUR
Excessive PA drain
current

D

Dissipation

Dissipated power in
tenths of a watt. See
^PD

HI DISS
Excessive dissipation:
supply voltage * PA
current – output power
exceeds limit

H

High Supply Voltage

millivolts

HI SPPLY
Excessive supply voltage

I

Input power

Input power, in tenths
of a watt. See ^PI

HI P IN
Excessive input power

L

Low supply voltage

millivolts

LO SPPLY
Insufficient DC supply
voltage

P

Forward Power

Forward (output)
power, in tenths of a
watt. See ^PF

HI P OUT
Excessive output power

R

Reflected power

Reflected (reverse)
power, in tenths of a
watt. See ^PV

HI PREFL
Excessive reflected
power. Improve SWR or