^CR (ATU Select Capacitors, GET and SET)
GET format: ^CR;
SET/RESPONSE format: ^Chh; where hh are two hexadecimal digits indicating the selected capacitors.
Examples:
^CR00; selects no capacitors.
^CRFF; selects all capacitors.
^CR80; selects only the largest capacitor.
^CRC1; selects the largest, second largest, and smallest capacitors.
Hex Digits
Relay
Capacitance (pF)
80
K116
1360
40
K115
660
20
K114
300
10
K113
150
08
K112
82
04
K111
40
02
K110
22
01
K109
10
The KXPA Utility Operate page displays capacitor relay settings as check boxes and as a total
capacitance.
It may take a few tens of milliseconds after issuing ^CR before the relays are changed.
Capacitor settings are changed by ATU tuning operations. ^CR set is ignored while tuning.
Capacitor relays are released while the ATU bypass relay is in its bypassed setting.