^CR (ATU Select Capacitors, GET and SET)

GET format: ^CR;

SET/RESPONSE format: ^Chh; where hh are two hexadecimal digits indicating the selected capacitors.

See

http://en.wikipedia.org/wiki/Hexadecimal

for a description of this notation.

Examples:

^CR00; selects no capacitors.
^CRFF; selects all capacitors.
^CR80; selects only the largest capacitor.
^CRC1; selects the largest, second largest, and smallest capacitors.

Hex Digits

Relay

Capacitance (pF)

80

K116

1360

40

K115

660

20

K114

300

10

K113

150

08

K112

82

04

K111

40

02

K110

22

01

K109

10

The KXPA Utility Operate page displays capacitor relay settings as check boxes and as a total
capacitance.

It may take a few tens of milliseconds after issuing ^CR before the relays are changed.

Capacitor settings are changed by ATU tuning operations. ^CR set is ignored while tuning.

Capacitor relays are released while the ATU bypass relay is in its bypassed setting.

^CR is meaningful only if the optional KXAT100 Antenna Tuner is installed.